Bug #26
closed
  
    
    
  
Abort retrying to consume NMEA message in case of bad messge.
 
        
        Added by Fernando Jose Capeletto Neto over 2 years ago.
        Updated over 2 years ago.
        
  
  
  
  Description
  
  If a bad message is sent, TrackHandler tries to decode and retries entering an infinite loop if is bad message.
Just abort and informs that the following message could not be decoded.
   
 
 
  
  
    
    
    
    
       - Due date changed from 04/03/2023 to 04/10/2023
 
    
    
     
   
  
  
    
    
    
    
       - Assignee set to Fernando Jose Capeletto Neto
 
       - Start date changed from 04/03/2023 to 04/05/2023
 
       - Status changed from New to In Progress
 
    
    
     
   
  
  
    
    
    
    
       - Status changed from In Progress to Testing
 
       - % Done changed from 0 to 90
 
    
    
     
   
  
  
    
    
    
    
       - Status changed from Testing to Merging
 
    
    https://gitlab.com/fernando.engineer/cms/TrackHandler/-/merge_requests/13
trackhandler-v1R3 | [2023-04-06 02:12:40.073] ERROR [e.f.c.t.h.c.SystemTrackConsumer] [60]: NMEA batch of messages not recognized, deleted from Rabbit queue. Batch: [$GPVTG,0.00,T,,M,0.0,N,0.0,K,A*02]
 
     
   
  
  
    
    
    
    
       - Status changed from Merging to Testing
 
    
    
     
   
  
  
    
    
    
    
       - Status changed from Testing to Deliver
 
    
    
     
   
  
  
    
    
    
    
       - Status changed from Deliver to Done
 
       - % Done changed from 90 to 100
 
    
    
     
   
  
  
    
    
    
    
       - Status changed from Done to Closed
 
    
    
     
   
  
 
  
  
  
 